Module configurations are written in JSON and node.js is required.
to be edited.
The following node.d modules are supported:
This module collects metrics from the configured solar power installation from Fronius Symo.
See netdata/conf.d/node.d/fronius.conf.md for more details.
Requirements
- Configuration file
fronius.confin the node.d netdata config dir (default:/etc/netdata/node.d/fronius.conf) - Fronius Symo with network access (http)
It produces per server:
- Power
- Current power input from the grid (positive values), output to the grid (negative values), in W
- Current power input from the solar panels, in W
- Current power stored in the accumulator (if present), in W (in theory, untested)
- Consumption
- Local consumption in W
- Autonomy
- Relative autonomy in %. 100 % autonomy means that the solar panels are delivering more power than it is needed by local consumption.
- Relative self consumption in %. The lower the better
- Energy
- The energy produced during the current day, in kWh
- The energy produced during the current year, in kWh
- Inverter
- The current power output from the connected inverters, in W, one dimension per inverter. At least one is always present.
Sample:
{
"enable_autodetect": false,
"update_every": 5,
"servers": [
{
"name": "Symo",
"hostname": "symo.ip.or.dns",
"update_every": 5,
"api_path": "/solar_api/v1/GetPowerFlowRealtimeData.fcgi"
}
]
}If no configuration is given, the module will be disabled. Each update_every is optional, the default is 5.