Notifications
You must be signed in to change notification settings - Fork 6
Expand file tree
/
Copy pathModbusExceptionCode.cs
More file actions
109 lines (101 loc) · 4.54 KB
/
ModbusExceptionCode.cs
File metadata and controls
109 lines (101 loc) · 4.54 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
namespace NModbus.Interfaces
{
public enum ModbusExceptionCode : byte
{
/// <summary>
/// The function code received in the query is not an
/// allowable action for the server. This may be
/// because the function code is only applicable to
/// newer devices, and was not implemented in the
/// unit selected. It could also indicate that the server
/// is in the wrong state to process a request of this
/// type, for example because it is unconfigured and
/// is being asked to return register values.
/// </summary>
IllegalFunction = 0x01,
/// <summary>
/// The data address received in the query is not an
/// allowable address for the server. More
/// specifically, the combination of reference number
/// and transfer length is invalid. For a controller with
/// 100 registers, the PDU addresses the first register
/// as 0, and the last one as 99. If a request is
/// submitted with a starting register address of 96
/// and a quantity of registers of 4, then this request
/// will successfully operate (address-wise at least)
/// on registers 96, 97, 98, 99. If a request is
/// submitted with a starting register address of 96
/// and a quantity of registers of 5, then this request
/// will fail with Exception Code 0x02 “Illegal Data
/// Address” since it attempts to operate on registers
/// 96, 97, 98, 99 and 100, and there is no register
/// with address 100.
/// </summary>
IllegalDataAddress = 0x02,
/// <summary>
/// A value contained in the query data field is not an
/// allowable value for server. This indicates a fault in
/// the structure of the remainder of a complex
/// request, such as that the implied length is
/// incorrect. It specifically does NOT mean that a
/// data item submitted for storage in a register has a
/// value outside the expectation of the application
/// program, since the MODBUS protocol is unaware
/// of the significance of any particular value of any
/// particular register.
/// </summary>
IllegalDataValue = 0x03,
/// <summary>
/// An unrecoverable error occurred while the server
/// was attempting to perform the requested action.
/// </summary>
ServerDeviceFailure = 0x04,
/// <summary>
/// Specialized use in conjunction with programming
/// commands.
/// The server has accepted the request and is
/// processing it, but a long duration of time will be
/// required to do so. This response is returned to
/// prevent a timeout error from occurring in the
/// client. The client can next issue a Poll Program
/// Complete message to determine if processing is
/// completed.
/// </summary>
Acknowledge = 0x05,
/// <summary>
/// Specialized use in conjunction with programming
/// commands.
/// The server is engaged in processing a long–
/// duration program command. The client should
/// retransmit the message later when the server is
/// free.
/// </summary>
ServerDeviceBusy = 0x06,
/// <summary>
/// Specialized use in conjunction with function codes
/// 20 and 21 and reference type 6, to indicate that
/// the extended file area failed to pass a consistency
/// check.
/// The server attempted to read record file, but
/// detected a parity error in the memory. The client
/// can retry the request, but service may be required.
/// </summary>
MemoryParityError = 0x08,
/// <summary>
/// Specialized use in conjunction with gateways,
/// indicates that the gateway was unable to allocate
/// an internal communication path from the input port
/// to the output port for processing the request.
/// Usually means that the gateway is misconfigured
/// or overloaded
/// </summary>
GatewayPathUnavailable = 0x0a,
/// <summary>
/// Specialized use in conjunction with gateways,
/// indicates that no response was obtained from the
/// target device. Usually means that the device is not
/// present on the network.
/// </summary>
GatewayTargetDeviceFailedToRespond = 0x0b
}
}